Trapped air reduces heating efficiency and causes noise. Learn safe, step-by-step methods to bleed individual radiators and purge an entire hot-water boiler system, plus tools, safety tips, and when to call a pro.

Why remove air from a hot-water boiler?

Air trapped in a hot-water boiler system causes cold spots in radiators or baseboards, noisy pipes, poor circulation and higher energy use. Identifying and removing that air restores even heat and quieter operation.

Quick checklist — tools & prep

  • Radiator key (or flat screwdriver for some valves)
  • Small adjustable wrench or pliers (for bleed valves or petcock)
  • Cloth / towel and a small bowl or bucket to catch drips
  • Hose for boiler drain (for full-system purge)
  • Protective gloves and eye protection
  • Thermometer (optional) to check radiator temperatures
  • Access to boiler manual and system pressure gauge

Before you start: turn off the boiler and let the system cool for radiator bleeding. Always have someone nearby if you need to refill the system or boost pressure.

hot-water-boiler-cases

Part A — Bleeding a single radiator or baseboard (most common, simple fix)

  1. Turn off heat / boiler and let the system cool enough to avoid scalding. Place a cloth/bucket under the bleed valve.
  2. Locate the bleed valve — usually at the top side of the radiator. Use a radiator key or screwdriver.
  3. Open the valve slowly until you hear a hissing (air escaping). Keep it open until a steady stream of water (no air) appears. Close the valve firmly but don’t overtighten.
  4. Check boiler pressure after bleeding. Many closed systems will need a small top-up to restore recommended pressure (consult your boiler manual). If pressure is too low, follow the manufacturer’s refilling procedure.

Notes: Some guides recommend turning off the circulator pump before bleeding individual radiators for safety—follow local practice and your boiler manual.

Part B — Purging (bleeding) an entire hydronic loop or the whole system

When multiple radiators or an entire zone have air, or air keeps returning, you may need a system purge rather than bleeding individual radiators.

Common purge method (hose + drain):

  1. Turn off power to boiler and circulate per manual (some systems use the circulator to help purge; see caution below). Close zone valves for zones you’re not purging.
  2. Attach a hose to the boiler drain (or purge port) and run it to a safe drain or bucket. Open the low return service valve (often near the boiler) to allow water and air to flow out.
  3. Open the supply/return valves for the zone being purged, then slowly open the drain/purge valve. If using the circulator to push water through, you’ll see air bubbles escape in the hose; continue until bubbles stop and clear water flows.
  4. Close valves, refill system to proper pressure, and restart boiler. Monitor for leaks and abnormal noises.

Important: Methods vary by system. Some systems are purged with the circulator running to push air to the drain; others advise isolating and purging each loop manually. Read the boiler/system manual or follow a HVAC-qualified technician’s instructions.

FangKuai hot-water-boiler H6 Cases

Automatic air vents & high-point vents

Modern systems often use automatic air vents at high points and air separators at the boiler to remove microbubbles continuously. If you repeatedly get air problems, inspect or replace automatic vents and the air separator—these small devices can resolve chronic air issues.

Troubleshooting & tips

  • If air returns after bleeding: check for a faulty auto-vent, a leaking fill valve, or circulating pump cavitation.
  • Cold top of radiator + warm bottom = trapped air (bleed that radiator).
  • If you must repeatedly add water to the system, there may be a leak or failed pressure regulator—get it checked.

Safety warnings

  • Never open pressurised parts or relief valves while the boiler is hot and under pressure. Let the system cool.
  • Watch system pressure when refilling—excessive pressure or running low pressure can damage the boiler.

When to call a professional

Call a qualified HVAC/plumbing technician if:

  • You cannot find or fix the source of recurring air.
  • Bleeding/purging is not removing air or system noises persist.
  • You’re uncomfortable working near the boiler or handling pressurized water.

Short FAQ

Q: How often should I bleed radiators?
A: Bleed when you notice cold spots, noises, or after system work—seasonal checks are a good practice.

Q: Can I bleed while the boiler is running?
A: For a single radiator it’s safer to turn off the boiler and pump; whole-system purges may require following manufacturer procedures that sometimes use the circulator. Don’t improvise—follow the manual or a tech.